Id1.3.182.11.10.3.10Effective Date2018‑08‑13 15:57:39
Statusdraft DraftVersion Label
NameEntryMedicalDevicesDisplay NameeHDSI Medical Devices
DescriptionThe medical devices entry content module describes the kind of device that is, or has been used by the patient
ContextPathname /
ClassificationCDA Entry Level Template
Open/ClosedClosed (only defined elements are allowed)
Used by / Uses
Used by 0 transactions and 1 template, Uses 1 template
Used by as NameVersion
1.3.182.11.10.2.4Containmentdraft eHDSI Medical Devices Coded Section2018‑08‑13 16:02:40
Uses as NameVersion
1.3.182.11.10.3.3Containmentdraft eHDSI Comment EntryDYNAMIC
Example
Example
<supply moodCode="EVN" classCode="SPLY">
  <templateId root="1.3.182.11.10.3.10"/>  <id nullflavor="NI"/>  <text>
    <reference value="#DevDescr"/>  </text>
  <effectiveTime nullFlavor="UNK"/>  <participant typeCode="DEV">
    <participantRole classCode="MANU">
      <id nullFlavor="UNK"/>      <playingDevice classCode="DEV" determinerCode="INSTANCE">
        <code code="84683006" codeSystem="2.16.840.1.113883.6.96"/>      </playingDevice>
    </participantRole>
  </participant>
</supply>
ItemDTCardConfDescriptionLabel
hl7:supply
R

The <supply> element shall be present. The moodCode attribute shall be EVN to reflect that a medical device has been provided.

Entrdotsices
@classCode
cs1 … 1FSPLY
@moodCode
cs1 … 1FEVN
hl7:templateId
II1 … 1MEntrdotsices
@root
uid1 … 1F1.3.182.11.10.3.10
hl7:id
II0 … *R

This optional element identifies the provision of the device. Not to be used as the identifier for the device itself.
The device identifier e.g. serial number can be provided under participant/participantRole/id

Entrdotsices
hl7:code
CD0 … 1RIf exists, code for the deviceEntrdotsices
hl7:text
ED0 … 1R

The <text> element references the part of the section narrative, which contains the description of the device.

Entrdotsices
hl7:reference
TEL1 … 1MEntrdotsices
@value
1 … 1RReference pointing to the narrative, typically #{label}-{generated-id}, e.g. #xxx-1
hl7:effectiveTime
TS.DATE1 … *R

The first <effectiveTime> element denotes the date the device was provided to the patient. For an implanted device, that is the date and time of implantation.
The cardinality is 1.

Entrdotsices
hl7:effectiveTime
TS.DATE0 … *The second <effectiveTime> element denotes the date the device has been removed from the patient.
The element is optional, cardinality is max 1.
Entrdotsices
hl7:expectedUseTime
TS.DATE0 … 1Expiration date of the implant.Entrdotsices
hl7:siteCode
CE0 … 1The Body site at which the implant has been performedEntrdotsices
hl7:entryRelationship
0 … 1Contains 1.3.182.11.10.3.3 eHDSI Comment Entry (DYNAMIC)Entrdotsices
@inversionInd
bl1 … 1Ftrue
@typeCode
cs1 … 1FSUBJ
hl7:participant
1 … 1R

The device is represented as a participant in the supply structure. The following descriptions apply to the device structure.

Entrdotsices
@typeCode
cs1 … 1FDEV
hl7:participantRole
1 … 1MEntrdotsices
@classCode
cs1 … 1FMANU
hl7:id
II0 … *R

The device ID is represented by the <id> element of the participant role. This element is optional, as not all device identifiers (serial numbers) may be known to the provider or patient.

Entrdotsices
@extension
st1 … 1R
@root
oid1 … 1F1.3.182.4.15
hl7:playingDevice
1 … 1R

The <playingDevice> element describes the device instance. The class code shall contain the value of "DEV", and the determiner code shall contain "INSTANCE".

Entrdotsices
@classCode
cs1 … 1FDEV
@determinerCode
cs1 … 1FINSTANCE
hl7:code
CE.EPSOS1 … 1R

The device code describes the type of device (e.g. arm prosthesis, arterial stent). It shall contain codes from the eSante_ImplantDeviceType value set OID 1.3.182.10.53.1.

Entrdotsices
 CONF
The value of @code shall be drawn from value set 1.3.182.10.53.1 eSante_ImplantDeviceType (DYNAMIC)
or
The value of @code shall be drawn from value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.8 epSOSMedicalDevices (DYNAMIC)
or
The value of @code shall be drawn from value set 1.3.182.10.63.1 eSante_NullValueRepresentation (DYNAMIC)
hl7:originalText
ED0 … 1REntrdotsices
hl7:manufacturerModelName
SC0 … 1Brand name from the manufacturer
Entrdotsices
 CONF
The value of @code shall be drawn from value set 1.3.182.10.54.1 eSante_ImplantManufacturerDeviceName (DYNAMIC)