Id1.3.182.11.12.3.1Effective Date2021‑04‑26 12:10:09
Statusdraft DraftVersion Label
NameObservationsSeroDisplay NameObservationsSero
Description
A Laboratory Battery Organizer is used to group Laboratory Observations (1.3.6.1.4.1.19376.1.3.1.6) for a battery of tests. Laboratory Battery Organizer, when present, SHALL be recorded as an organizer under the Laboratory Data Processing Entry as demonstrated.
ContextPathname /
ClassificationCDA Entry Level Template
Open/ClosedClosed (only defined elements are allowed)
Used by / Uses
Used by 0 transactions and 1 template, Uses 0 templates
Used by as NameVersion
1.3.182.11.12.2.1Containmentdraft Maladie déclarable sero2021‑04‑26 12:13:20
Example
Example
<organizer classCode="CLUSTER" moodCode="EVN">
  <templateId root="1.3.182.11.12.3"/>  <statusCode code="completed"/>  <component>
    <!-- test quantitatif IgG -->
    <observation classCode="OBS" moodCode="EVN">
      <templateId root="1.3.182.11.12.3.1"/>      <code code="COVIDSERO-1" displayName="SARS-CoV-2 (COVID-19) IgG [Units/volume] in DBS" codeSystem="1.3.182.5.21"/>      <statusCode code="completed"/>      <value xsi:type="PQ" value="7" unit="RU/mL"/>      <!-- 3 possible codes : NEG:negativ, E:Equivocal, POS:positiv-->
      <interpretationCode code="NEG"/>      <methodCode code="ELISA">
        <originalText>Euroimmun Anti-SARS-CoV-2-QuantiVac-ELISA</originalText>      </methodCode>
    </observation>
  </component>
  <!-- Human Comments/Interpretation -->
  <component>
    <observation classCode="OBS" moodCode="EVN">
      <templateId root="1.3.182.11.9.3.1"/>      <code code="48767-8" codeSystem="2.16.840.1.113883.6.1"/>      <statusCode code="completed"/>      <value xsi:type="ST">The patient is not immune</value>    </observation>
  </component>
</organizer>
ItemDTCardConfDescriptionLabel
hl7:organizer
1 … 1MObsedotsSero
@classCode
cs1 … 1FCLUSTER
@moodCode
cs1 … 1FEVN
hl7:templateId
II1 … 1MObsedotsSero
@root
uid1 … 1F1.3.182.11.12.3.1
hl7:statusCode
CS1 … 1MObsedotsSero
@code
CONF1 … 1Fcompleted
hl7:component
1 … 1MObsedotsSero
hl7:observation
1 … 1MObsedotsSero
@classCode
cs1 … 1FOBS
@moodCode
cs1 … 1FEVN
hl7:code
CV1 … 1MWhat is measuredObsedotsSero
@code
CONF1 … 1FCOVIDSERO-1
@codeSystem
1 … 1F1.3.182.5.21
@displayName
1 … 1FSARS-CoV-2 (COVID-19) IgG [Units/volume] in DBS
hl7:statusCode
1 … 1MObsedotsSero
@code
1 … 1Fcompleted
hl7:value
PQ1 … 1MObsedotsSero
@value
1 … 1R
@unit
cs1 … 1R
@xsi:type
1 … 1FPQ
hl7:interpretationCode
1 … 1MObsedotsSero
@code
1 … 1R
 Schematron assertrolered error 
 test@code="NEG" or @code="E" or @code="POS" 
 MessagePossible values for code are NEG (Negatie), E (Equivocal) or POS (Positive) 
hl7:methodCode
1 … 1MObsedotsSero
@code
1 … 1RGeneric laboratory method used
hl7:originalText
1 … 1MFull name of the commercial kitObsedotsSero
hl7:component
1 … 1MObsedotsSero
hl7:observation
1 … 1MObsedotsSero
@classCode
cs1 … 1FOBS
@moodCode
cs1 … 1FEVN
hl7:templateId
1 … 1MObsedotsSero
@root
uid1 … 1F1.3.182.11.9.3.1
hl7:code
CV1 … 1MInterpretation in a human-friendly textObsedotsSero
@code
CONF1 … 1F48767-8
@codeSystem
1 … 1F2.16.840.1.113883.6.1
hl7:statusCode
1 … 1MObsedotsSero
@code
1 … 1Fcompleted
hl7:value
1 … 1MObsedotsSero
@xsi:type
1 … 1FST